GE Monogram ZDWI240WII User Manual

Design Guide with  
Installation  
Instructions  
Wine Chiller, Wine Reserve  
and Beverage Center  
monogram.com  
Design Guide  
THE INSTALLATION SPACE (cont.)  
THE INSTALLATION SPACE  
Flush  
Installation  
Dim. A  
Filler panel or cleat  
to be set back even  
with front of case.  
CABINET  
CABINET  
Front edge of product case  
Front face  
110°  
120°  
These products will fit flush to  
adjacent cabinets when installed  
with a Dim. A-width filler panel  
or cleat. The filler panel should  
be recessed or set back behind  
the door and even with the front  
edge of the product case.  
NOTE:  
Handle and handle  
standoff depth is 1-3/4"  
Product  
Dim. A  
ZDWI240, ZDBI240  
ZDWC240, ZDWR240  
ZDBC240, ZDBR240  
1"  
*For a standard installation of Custom-Framed unit: The  
product must be installed so that the front face will project 2"  
forward of adjacent cabinets. This position will allow a full door  
swing and prevent interference with adjacent cabinetry. The  
opening between cabinets must be 23-3/4" minimum.  
1/2"  
1/2"  
*For a standard installation of Stainless Steel unit: The product  
must be installed so that the front face will project 1-3/4"  
forward of adjacent cabinets. This position will allow a full door  
swing and prevent interference with adjacent cabinetry. The  
opening between cabinets must be 23-3/4" minimum.  
Standard  
Installation  
**For a flush installation of Stainless Steel unit: Install a  
1/2"-wide filler strip on the hinge side. The filler strip will act as  
a spacer between the door case and adjacent cabinets and will  
prevent interference with the cabinet door swing. Recess the  
filler strip 2" back from the front face of the unit, or even with  
the front edge of the product case (behind the gasket). The width  
of the opening must be 24-1/4" (including the 1/2" filler strip).  
***For a flush installation of Custom-Framed unit: Install a  
1"-wide filler strip on the hinge side. The filler strip will act as  
a spacer between the door case and adjacent cabinets and  
will prevent interference with the cabinet door swing. Recess  
the filler strip 2" back from the front face of the unit, or even with  
the front edge of the product case (behind the gasket). The width  
of the opening must be 24-3/4" (including the 1" filler strip).  
CABINET  
CABINET  
Front edge of product case  
Front face  
Dim. A  
110°  
120°  
In a standard installation,  
the product will project forward  
of adjacent cabinets. See Dim. A.  
Product  
Dim. A  
2"  
ZDWI240, ZDBI240  
ZDWC240, ZDWR240  
ZDBC240, ZDBR240  
1-3/4"  
1-3/4"  
• The wine chiller, wine reserve and beverage center can  
be installed freestanding.  
Additional Specifications  
A 120 volt 60Hz., 15 or 20 amp power supply is required.  
An individual properly grounded branch circuit or circuit  
breaker is recommended. Install a properly grounded  
3-prong electrical receptacle recessed into the back wall  
as shown. Electrical must be located on rear wall as shown.  
NOTE: GFI (ground fault interrupter) is not recommended.  
3
Design Guide  
PRODUCT CLEARANCES  
SIDE-BY-SIDE INSTALLATIONS  
Increase storage capacity by installing two Monogram  
beverage centers, wine chillers or wine reserves together.  
Or, for a complete refreshment center, install any two  
of these units together.  
The stainless steel wine chiller, wine reserve and  
beverage center is factory set for a 110° door swing.  
Models that accept custom panels have a 95° door  
swing.  
When installed in a corner:  
• A side-by-side installation requires at least a 47-1/2"-  
wide minimum opening for standard installation and  
a 48-1/2"-wide minimum opening for flush installation  
of stainless steel models. A 49-1/2"-wide minimum  
opening is required for side-by-side flush installation  
of custom framed models.  
Allow 4" min. clearance on the hinge side for the 90°  
door swing and to allow racks to slide out.  
• Allow 10" minimum clearance on the hinge side for  
a full 110° door swing. (Models ZDWI240WII and  
ZDBI240WII have a 95° door swing.)  
NOTE: Custom handle clearances may vary, depending  
on custom handle depth.  
• Products must operate from separate, properly  
grounded receptacles.  
10" Minimum  
to Wall  
90° Door Swing  
21-5/8"  
23-5/8"  
90ϒ  
110°*  
*95° Door Swing on Custom Frame Models  
4" Minimum  
to Wall  
• The door swing is reversible on all models. If desired,  
change the door swing before installation or before  
installing the custom frame panel.  
Choose the location:  
• These products may be closed in on the top and  
three sides as long as the front is unobstructed for air  
circulation and proper access to the door.  
• Do not install these products where the temperature  
will go below 55°F (13°C) or above 90°F (32°C).  
• Do not install where it will be subject to direct sunlight,  
heat or moisture.  
• These products are not designed to be stacked one  
over the other.  
Black or Stainless Steel Toekick Options  
• These products are shipped with a black toekick  
installed. An optional stainless steel toekick is also  
supplied with each product. For shipping purposes, the  
stainless steel toekick is secured to the back of the unit.  
4
Installation Instructions  
TOOLS REQUIRED  
• #2 Phillips screwdriver  
• Adjustable wrench  
STAINING WOOD DRAWER FRONTS  
The drawer fronts are unfinished cherry wood. During  
use, oil from hands may accumulate and stain the  
wood.  
• The drawer fronts may be stained and sealed to  
match adjacent cabinetry. The tinted glass will make  
the stained wood appear darker. A true color match  
can be seen only when the door is opened.  
• Apply the stain and sealer according to the  
manufacturer’s instructions. To avoid unpleasant  
odor, keep the door open to ventilate and allow  
the stain/sealer to dry completely before using  
the product.  
PARTS SUPPLIED  
• Monogram nameplate  
• Hardware for changing door swing  
• Optional stainless steel toekick with screws and  
spacers  
• Left and right side hinge covers  
• Top screw hole cover  
GROUNDING THE WINE CHILLER,  
WINE RESERVE AND BEVERAGE  
CENTER  
INSTALLING THE CUSTOM FRAME PANEL  
Go to page 6 for custom frame panel size, depending  
on your cabinet size and style.  
IMPORTANT –  
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE  
PROPERLY GROUNDED.  
Please read carefully.  
• Install a custom handle of your choice onto the  
custom panel before the panel is secured to the door.  
• The custom panel should be installed before sliding  
the product into the installation location.  
The power cord of this appliance is equipped with  
a three-prong (grounding) plug which mates with a  
standard three-prong (grounding) wall receptacle to  
minimize the possibility of electric shock hazard from  
this appliance.  
STEP 1 REMOVE PACKAGING  
• Remove corner blocks and foam drawer stops.  
• Remove all packing material, tape and protective  
plastic coverings.  
• Remove stainless steel toekick taped to the back  
of the unit.  
Have the wall outlet and circuit checked by a qualified  
electrician to make sure the outlet is properly grounded.  
Where a standard 2-prong wall outlet is encountered, it  
is your personal responsibility and obligation to have it  
replaced with a properly grounded 3-prong wall outlet.  
CAUTION:  
Small objects are a choke  
hazard for children. Remove and discard any parts  
not used.  
DO NOT, UNDER ANY  
CIRCUMSTANCES, CUT  
OR REMOVE THE THIRD  
(GROUND) PRONG  
MISE EN GARDE :  
Les petits  
objets peuvent étrangler les enfants. Il faut jeter toutes  
les piéces qui ne sont pas utilisées.  
FROM THE POWER CORD.  
DO NOT USE AN ADAPTER PLUG TO CONNECT THE  
REFRIGERATOR TO A 2-PRONG OUTLET.  
DO NOT USE AN EXTENSION CORD WITH THIS  
APPLIANCE.  