Design Guide with
Installation
Instructions
Wine Chiller, Wine Reserve
and Beverage Center
monogram.com
Design Guide
THE INSTALLATION SPACE (cont.)
THE INSTALLATION SPACE
Flush
Installation
Dim. A
Filler panel or cleat
to be set back even
with front of case.
CABINET
CABINET
Front edge of product case
Front face
110°
120°
These products will fit flush to
adjacent cabinets when installed
with a Dim. A-width filler panel
or cleat. The filler panel should
be recessed or set back behind
the door and even with the front
edge of the product case.
NOTE:
Handle and handle
standoff depth is 1-3/4"
Product
Dim. A
ZDWI240, ZDBI240
ZDWC240, ZDWR240
ZDBC240, ZDBR240
1"
*For a standard installation of Custom-Framed unit: The
product must be installed so that the front face will project 2"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.
1/2"
1/2"
*For a standard installation of Stainless Steel unit: The product
must be installed so that the front face will project 1-3/4"
forward of adjacent cabinets. This position will allow a full door
swing and prevent interference with adjacent cabinetry. The
opening between cabinets must be 23-3/4" minimum.
Standard
Installation
**For a flush installation of Stainless Steel unit: Install a
1/2"-wide filler strip on the hinge side. The filler strip will act as
a spacer between the door case and adjacent cabinets and will
prevent interference with the cabinet door swing. Recess the
filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket). The width
of the opening must be 24-1/4" (including the 1/2" filler strip).
***For a flush installation of Custom-Framed unit: Install a
1"-wide filler strip on the hinge side. The filler strip will act as
a spacer between the door case and adjacent cabinets and
will prevent interference with the cabinet door swing. Recess
the filler strip 2" back from the front face of the unit, or even with
the front edge of the product case (behind the gasket). The width
of the opening must be 24-3/4" (including the 1" filler strip).
CABINET
CABINET
Front edge of product case
Front face
Dim. A
110°
120°
In a standard installation,
the product will project forward
of adjacent cabinets. See Dim. A.
Product
Dim. A
2"
ZDWI240, ZDBI240
ZDWC240, ZDWR240
ZDBC240, ZDBR240
1-3/4"
1-3/4"
• The wine chiller, wine reserve and beverage center can
be installed freestanding.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is required.
An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back wall
as shown. Electrical must be located on rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
3
Design Guide
PRODUCT CLEARANCES
SIDE-BY-SIDE INSTALLATIONS
Increase storage capacity by installing two Monogram
beverage centers, wine chillers or wine reserves together.
Or, for a complete refreshment center, install any two
of these units together.
The stainless steel wine chiller, wine reserve and
beverage center is factory set for a 110° door swing.
Models that accept custom panels have a 95° door
swing.
When installed in a corner:
• A side-by-side installation requires at least a 47-1/2"-
wide minimum opening for standard installation and
a 48-1/2"-wide minimum opening for flush installation
of stainless steel models. A 49-1/2"-wide minimum
opening is required for side-by-side flush installation
of custom framed models.
• Allow 4" min. clearance on the hinge side for the 90°
door swing and to allow racks to slide out.
• Allow 10" minimum clearance on the hinge side for
a full 110° door swing. (Models ZDWI240WII and
ZDBI240WII have a 95° door swing.)
NOTE: Custom handle clearances may vary, depending
on custom handle depth.
• Products must operate from separate, properly
grounded receptacles.
10" Minimum
to Wall
90° Door Swing
21-5/8"
23-5/8"
90ϒ
110°*
*95° Door Swing on Custom Frame Models
4" Minimum
to Wall
• The door swing is reversible on all models. If desired,
change the door swing before installation or before
installing the custom frame panel.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the door.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 90°F (32°C).
• Do not install where it will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one
over the other.
Black or Stainless Steel Toekick Options
• These products are shipped with a black toekick
installed. An optional stainless steel toekick is also
supplied with each product. For shipping purposes, the
stainless steel toekick is secured to the back of the unit.
4
Installation Instructions
TOOLS REQUIRED
• #2 Phillips screwdriver
• Adjustable wrench
STAINING WOOD DRAWER FRONTS
The drawer fronts are unfinished cherry wood. During
use, oil from hands may accumulate and stain the
wood.
• The drawer fronts may be stained and sealed to
match adjacent cabinetry. The tinted glass will make
the stained wood appear darker. A true color match
can be seen only when the door is opened.
• Apply the stain and sealer according to the
manufacturer’s instructions. To avoid unpleasant
odor, keep the door open to ventilate and allow
the stain/sealer to dry completely before using
the product.
PARTS SUPPLIED
• Monogram nameplate
• Hardware for changing door swing
• Optional stainless steel toekick with screws and
spacers
• Left and right side hinge covers
• Top screw hole cover
GROUNDING THE WINE CHILLER,
WINE RESERVE AND BEVERAGE
CENTER
INSTALLING THE CUSTOM FRAME PANEL
Go to page 6 for custom frame panel size, depending
on your cabinet size and style.
IMPORTANT –
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
Please read carefully.
• Install a custom handle of your choice onto the
custom panel before the panel is secured to the door.
• The custom panel should be installed before sliding
the product into the installation location.
The power cord of this appliance is equipped with
a three-prong (grounding) plug which mates with a
standard three-prong (grounding) wall receptacle to
minimize the possibility of electric shock hazard from
this appliance.
STEP 1 REMOVE PACKAGING
• Remove corner blocks and foam drawer stops.
• Remove all packing material, tape and protective
plastic coverings.
• Remove stainless steel toekick taped to the back
of the unit.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a standard 2-prong wall outlet is encountered, it
is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
CAUTION:
Small objects are a choke
hazard for children. Remove and discard any parts
not used.
DO NOT, UNDER ANY
CIRCUMSTANCES, CUT
OR REMOVE THE THIRD
(GROUND) PRONG
MISE EN GARDE :
Les petits
objets peuvent étrangler les enfants. Il faut jeter toutes
les piéces qui ne sont pas utilisées.
FROM THE POWER CORD.
DO NOT USE AN ADAPTER PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG OUTLET.
DO NOT USE AN EXTENSION CORD WITH THIS
APPLIANCE.
5
|